Home > Products > Elevator Cable > Flat Elevator Cable TVVBP

 

TVVBP Flat Elevator Cable

TVVBP Flat Elevator Cable

 

Part-No.
Type
Specification
Width(MM)

Thickness
(MM)

Density Kg/Km
Shape
EKM 804 00
54
24
TVVBP
24*0.75+2*2P*0.75
44.3
9.0
879
Twist
EKM 804 00
54
30
TVVBP
30*0.75+2*2P*0.75
53.1
8.3
990
Twist
EKM 804 00
54
36
TVVBP
36*0.75+2*2P*0.75
56.8
9.0
1116
Twist
EKM 804 00
54
40
TVVBP
40*0.75+2*2P*0.75
64.2
8.3
1169
Twist
EKM 804 00
54
42
TVVBP
42*0.75+2*2P*0.75
63.0
9.0
1224
Twist
EKM 804 00
54
48
TVVBP
48*0.75+2*2P*0.75
69.1
9.0
1331
Twist
EKM 804 00
54
54
TVVBP
54*0.75+2*2P*0.75
75.3
9.0
1438
Twist
EKM 804 00
54
60
TVVBP
60*0.75+2*2P*0.75
81.4
9.0
1546
Twist
EKM 804 00
54
66
TVVBP
66*0.75+2*2P*0.75
87.6
9.0
1653
Twist

 

Technical data:

Three kinds of shielding: aluminum foil; bare copper; aluminum foil+bare copper

Rated voltage: 300/500V
Test voltage: 2500V
Minimum bending radius: 0.3m≤L≤0.6M
Burning vertically test: GB/T1 8380.1-2001,
IEC60332-1:1993 test passed
Used under the normal conditions,temperature of conductor is lower then 70,
Temperature range:-15 to +70
TVVBG(intervvist) free suspension length exceed 80 meters,and the lift speed must not exceed 10m/s

 

Standards:

GB5023.6, IEC60227-6, EN50214

 

Applications:

As control and signal cable for elevator as well as moving nachine parts, its bending radius is smaller compared with round cables due to the closely packed shielded cores or bundles, It can be installed in dry and damp rooms. The copper shielded single or respectively bundled cores make this cable ideally suit for the situations where there are electromagnetic compatibiliy interference(EMC)

 

Structure:

Conductor: Fine strands of bare copper wire, acc. to VDE 0295,class 5
Insulation: special PVC
Colour: yellow, white, orange with black number digital coding
Bearing: steel rope
COAX: Optional
Sheath: flexible PVC , cold resistance, flame resistance
Colour: Grey(RAL 7001)